General operation procedure of multi media filter

Equipment water production: 1 washing (1) Open the washing drainage valve mv116. Open the water inlet valve mv111. Washing for 3 minutes or effluent turbidity less than 1 NTU is qualified. 2. Water production Outlet valve mv112. Close the washing drainage valve mv116. Start making water. Sy...
2021-06-16

Reverse osmosis membrane unit conversion, temperature, conductivity, installation and disassembly is so simple

1、 Unit conversion of reverse osmosis membrane 1. Unit conversion of size, pore diameter, diameter, area and water yield of imported reverse osmosis membrane? A: in China's water treatment process, the length unit is generally expressed in mm, and the calibration unit of imported equipment nee...
2021-06-11

Brief analysis of dosing principle in each stage of water treatment system

Charging system of boiler water 1. Ammonia: adjusting pH value 2. Hydrazine: deaeration The two agents are pumped to deaerator through dosing to adjust pH value of feed water and remove oxygen in water. 3. Phosphate (trisodium phosphate) is added directly to the boiler drum. It also regulates pH...
2021-06-09

Detailed explanation of water plant technology! Shenzhen Hongjie Water Technology Co., Ltd

Water is the source of life, water accounts for 70% of the human body composition. Scientific research shows that the average daily water demand of adults is more than 2500ml, which can be said that water quality is the basic guarantee of health. Turn on the tap and the tap water flows out slowly. ...
2021-06-08

Practical part: reverse osmosis membrane replacement site operation process

The first step preparation 1. Prepare all possible tools for construction Including: rubber boots, rubber gloves, protective glasses, wrench (remove the end cover of module housing), pipe clamp, glycerin, etc 2. Clean the upstream water inlet pipeline; 3. Carefully evalsuate the quality of the in...
2021-06-07

Application of industrial ultra pure water equipment in semiconductor industry

With the rapid development of the semiconductor industry, the requirements for semiconductor production technology are higher and higher. Semiconductor production has strict requirements on water consumption. The application of industrial ultra pure water equipment in the industry has played an impo...
2021-06-07

Brief introduction of two stage DTRO process for 100 t / D landfill leachate treatment

Sanitary landfill is the most common domestic waste treatment technology in China. Through aerobic and anaerobic reaction, the inorganic substances and organic matter produced by decomposition in the waste will form the landfill leachate with rainwater, water brought by the garbage itself and the wa...
2021-06-05

99% of water pumps are so bad! Shenzhen Hongjie water

In sewage treatment plant, water pump is the most commonly used moving equipment, and also the movable equipment which is prone to problems. The treatment of pump failure should be based on specific problems and actual analysis, and the principle of "outside first and then inside" should be followed...
J9九游会